Titan 3 Rap-O-Round: sizes and cutout on the manhole shield sheet

Kundel’s Titan 3 Rap-O-Round brochure lists three ST lengths in the 4-foot column and shows where the standard cutout sits. Neither is a working clearance for an individual box.

Updated November 20, 20263 min read

The Titan 3 manhole shield

The January 2001 Titan Manhole Shields sheet has separate panels for the 3 and 5 Rap-O-Round. Kundel also lists them separately in its manhole shield range. The printed date is a copyright, not a drawing revision for a particular build. [4] [3]

Kundel describes the Titan 3 as a shield for manhole work. A shield resists cave-in forces to protect people inside; unlike shoring, it does not support the excavation sides. That distinction says nothing about a particular box’s permissible loads or depth. [3] [1]

Three ST entries in the Titan 3 panel’s 4-foot column

The Titan 3 Rap-O-Round panel lists 8′ - ST, 10′ - ST and 12′ - ST under 4′. The same three lengths appear with K suffixes under 6′ and 8′. The 5′ and 10′ columns refer readers to the factory rather than listing sizes. [4]

The brochure’s shield-weight column does not state a unit or identify the fitted components. The separate machine-weight column is not the weight of the shield. Use the row to identify a size, not to assign an assembled weight. [4]

Where the cutout is shown

The inside view places the standard cutout at the lower edge. That tells you where the brochure illustrator put the notch, not which walls of an individual box are notched or what clear opening the box will provide. [4]

The inside view shows a standard bottom notch. Its location in the drawing does not establish the opening geometry or number of cutouts on an identified unit.Historical INSIDEviewStandard cutout depictedas a notch at the loweredge.Actual manhole unitWhich walls are notched,and what is the clearopening?
A cutout label is not a location on an identified box.

For the Titan 3, Kundel lists a 3-inch side wall, a 24-inch knife-edge taper and ¾-inch pounding pads. The sheet also shows top, front/back and inside views. The inside view depicts a notch at the bottom labeled ‘Standard Cut Out 2′ x 2′.’ [4]

Which walls have a cutout, its clear opening and the spreader that fits the sockets are questions for the dimensioned drawing of the unit in hand. The standard notch illustration cannot establish pipe clearance there. [4] [3]

Design limits in use

Where a shield design uses manufacturer’s tabulated data, follow all manufacturer specifications, recommendations and limitations. A departure needs specific written manufacturer approval; keep the written information at the jobsite while the system is constructed. Do not load the shield beyond its design or allow workers inside during installation, removal or vertical movement. [2] [3]

Handling an identified Titan 3

The sheet notes separately sold spreaders and larger or custom shields. To evaluate the box in hand, identify its components, cutout geometry and clear opening on its own drawing, and obtain the weight and handling instructions for that build. [4] [3]

“Production Depth,” “Shield Wt.” and “Mach Wt.” are catalog headings, not a site-specific depth limit or a load chart for a machine. [4] [3]

A competent person must examine damaged protective equipment. If they cannot assure it can support the intended loads or is otherwise suitable, it must be removed from service and evaluated and approved by a registered professional engineer before return. [2]