Two models in the Basic 3 table
Both K-style models are nominally 7.5 feet high. Compared with the 8-foot model, the 10-foot model adds 2 feet of nominal length, 24 inches of published internal front-to-rear clearance and 300 listed pounds. Those are differences along the box and in the weight column. Nothing in the comparison shows that the longer box is wider or allows a larger pipe beneath its spreaders. [2]
| Manufacturer field | B3 - 7.5′ X 8′ - K | B3 - 7.5′ X 10′ - K |
|---|---|---|
| Nominal height × length (ft) | 7.5 × 8 | 7.5 × 10 |
| Style / spreader table | K / A | K / A |
| Weight (published lb) | 1,395 | 1,695 |
| Items included in published weight | Unknown | Unknown |
| Horizontal clearance: front to rear, along the box (in) | 84 | 108 |
| Horizontal clearance: inside width across the sides | Not given | Not given |
| Vertical clearance: rear pipe (in) | 27 | 27 |
| Vertical clearance: front pipe (in) | 27 | 27 |
Read the clearance on the right axis
The longer K model has more front-to-rear clearance but the same vertical pipe clearance. Neither row states the width between the sides. [2]
H × L means height × length. The 84 and 108 inches are measured along the box; neither tells you its width across the sides. The 27 inches is vertical clearance at the front and rear, not a permitted pipe diameter. [2]
Both K rows point to spreader table A, which lists length and weight entries and is labeled “3″ SPR SET OF 4.” For example, the 30-inch entry reads 80 lb. The rows do not say which length is fitted or whether the box weight includes the spreaders. Do not add or subtract an assumed spreader weight. [2]
Match the table to the unit before assessing fit
Use the upper panel headed ‘The Basic 3 All Steel Trench Box.’ Both identifiers begin B3 and the ‘Weight’ column is explicitly labeled ‘POUNDS.’ The lower panel describes the Basic 5; its model and spreader tables do not apply to these B3 rows. [2]
Match the B3 marking and unit identifier to a drawing that gives overall width for the excavation, inside width for the crew, and openings at the pipe. Confirm the fitted spreaders, assembled weight and applicable design limits for that configuration. [2] [1]
Sources
- 29 CFR 1926.652: Requirements for protective systemsOccupational Safety and Health Administration
- The Basic 3 All Steel Trench Box — Basic 3 model weights, clearances and spreader table AKundel Industries