A material container and a protective system serve different purposes
A bedding box—called a stone box or stone mizer in the supplied manufacturer overview—is a container used on a jobsite to hold bedding material for utility line installation. US OSHA's excavation definitions describe protective systems as methods of protecting employees from cave-ins and related hazards, including support and shield systems, sloping and benching. The two purposes are distinct: this directory treats bedding and stone boxes as material-handling equipment, not as cave-in protection. The supplied records use bedding and stone labels; none is labeled a gravel box. [3] [1]
Basic: read the bedding table, not the shield table
The Basic PDF's lower bedding table lists four labels: SB - 4.5 CYD, SB - 6 CYD, SB - 7.5 CYD and SB - 9 CYD. It also names a walk bar, drag bar and roll-up bottom—feature labels, not handling instructions. The page's upper Basic 6/8 trench-shield section is separate equipment data; do not transfer its values. For a matched unit, request the separate outside and inside dimensions and weight fields. No printed revision date appears, and the labels do not establish current stock, actual capacity or a machine pairing. [4]
Read the lower Basic Bedding table
Standard: match the code and the source status
The Standard group on the Titan sheet lists five printed codes: 4-CYD-SB, 6-CYD-SB, 7.5-CYD-SB, 9-CYD-SB and 12-CYD-SB. The sheet carries a Sept. 2005 copyright notice, which is a printed date on the document, not confirmation of a current revision or current availability. It also prints walk bar, drag bar and High Tapper Back labels, but no handling procedure. Treat these names and cubic-yard labels as record identifiers; they do not establish a certified payload, actual unit identity or machine pairing. [5]
Read the Standard group in the Titan sheet
Heavy Duty: retain the ambiguous row label
The Heavy Duty group prints three codes: 7.5-CYD-SB, 9-CYD-SB-HD and 12-CYD-SB-HD. The 7.5-CYD-SB code also appears under Standard, so it needs manufacturer clarification rather than an assumed -HD suffix. The sheet also labels optional skids; verify that feature against the actual unit and its documents, without treating it as a compatibility statement or a movement instruction. [5]
Read the Heavy Duty group in the same sheet
Separate material, machine and site inputs
An optional inquiry worksheet can record material type and volume, actual load mass, unit and model, document revision, configuration, empty and loaded limits, permitted handling instructions, the exact machine and attachment, and the relevant chart. Space, route, set-down, edge and falling-load observations can also be recorded. Do not calculate capacity or infer that a loaded box can be moved; a cubic-yard label alone does not establish load mass or machine ability. Federal excavation requirements for materials and equipment near edges and falling loads depend on site conditions and applicable provisions, not on a box's product record. [2]
Read the federal excavation site-safety reference
Use the directory to request matched records
Use the linked document cards to request the exact public record for the model label you are checking, then ask the manufacturer to confirm the unit identity, revision and any unresolved row. This page indexes reviewed primary documents; it does not approve a unit, verify current stock, supply a price or replace project-specific engineering or site-safety decisions. Model and workflow pages should be consulted only after their relationships to these records are verified. [3] [4] [5] [2] [1]
Sources
- Occupational Safety and Health Administration: 1926.650 — scope and definitions
- Occupational Safety and Health Administration: 1926.651 — specific excavation requirements
- Kundel: Bedding-box overview — purpose and directory labels only
- Kundel: Basic Bedding lower table
- Kundel: Titan Bedding Box — Standard and Heavy Duty records