Where a shield protects workers
A trench box is designed to withstand cave-in forces and protect employees inside it. The approach is not part of that protection simply because it leads to the box. OSHA separately requires protection during entry and exit. [1] [3]
Shoring supports the excavation sides; shielding protects the people inside a structure if the sides give way. Neither a nearby footing nor the ground below a shield is supported merely because the box is in place. [1]
Loads and sudden movement
Section 1926.652(g)(1)(i) prohibits loads beyond the shield’s design. Where the design uses manufacturer tabulated data, the specifications, recommendations and limitations for the actual configuration govern; a deviation needs specific written manufacturer approval. [3]
A shield must also be installed to restrict lateral or other hazardous movement if sudden lateral loads are applied (§1926.652(g)(1)(ii)). Capacity and restraint are separate requirements. [3]
Work inside the protected area can still involve hazards the shield does not address. OSHA bars employees from standing under loads handled by lifting or digging equipment and requires protection from loose rock or soil falling or rolling from an excavation face. Excavated material or equipment must also be kept at least 2 feet from the edge or restrained by retaining devices. NIOSH notes there is no reliable warning when a trench fails. [2] [4]
Entering and Leaving the Protected Area
Mark two different questions against any proposed way in or out: does it provide a means of egress, and what protects people from a cave-in as they enter or leave the shielded area? A route might be drawn clearly enough to answer the first without answering the second. [2] [3]
Under §1926.652(g)(1)(iii), employees must be protected from cave-ins as they enter or leave the area protected by a shield. Consider the path to the opening, not just the place where workers stand once inside. [3]
A trench 4 feet deep or more must have a stairway, ladder, ramp or other safe means of egress within 25 feet of lateral travel. Meeting that travel limit does not, by itself, protect an exposed stretch of the route against cave-ins. [2] [1]
When the shield must be empty
No employee may remain in a shield during installation, removal or vertical movement (§1926.652(g)(1)(iv)), however short the move. [3]
Equipment condition is another limit. Section 1926.652(d) requires protective-system materials and equipment to be free from damage or defects that could impair proper function, and manufactured equipment must be used and maintained consistently with the manufacturer's recommendations. A competent person must examine damaged equipment; if they cannot assure it can support the intended loads, it is removed from service and must be evaluated and approved by a registered professional engineer before return. [3]
When excavation below a shield is allowed
Under §1926.652(g)(2), excavation up to 2 feet below the shield bottom is permitted only if the shield is designed for forces calculated for the full trench depth and there are no indications, while the trench is open, of possible soil loss from behind or below the shield. Both conditions must hold. [3]
Sources
- 29 CFR 1926.650: Scope, application, and definitions applicable to this subpartOccupational Safety and Health Administration
- 29 CFR 1926.651: Specific excavation requirementsOccupational Safety and Health Administration
- 29 CFR 1926.652: Requirements for protective systemsOccupational Safety and Health Administration
- Preventing Worker Deaths from Trench Cave-ins (NIOSH Workplace Solutions 2011-208)CDC and NIOSH