Skip to content
Trench ShoringBoxes

Shoring guides

Fin Form shoring panels: what the plywood supports

OSHA describes a limited role for plywood in controlling raveling between shores. See how that differs from identifying a Finn Form panel or a covered Kundel Tren-Shore arrangement.

Updated November 20, 20266 min read

Where the panel sits in the load path

Follow the load in the direction of the arrows, not the order of construction. In the cited Appendix D note, the plywood contains raveled soil and passes that load to a primary member. Naming a plywood product does not turn it into the upright or rail that receives the load. [4] [5]

Which member carries the load?Raveled soil fragments lead to a sheeting panel, then to an isolated primary member. Arrows denote transfer of the raveled-soil load, not installation order. What carries the load from raveled soil?Roles in the cited Appendix D note • arrows show transfer, not installation order Raveled soilLoose material at the facePlywood sheetingContains and transfers this loadPrimary memberFor example, an upright or rail
Load transfer in the limited plywood role described by OSHA.

In the limited plywood application described in Appendix D, the sheeting catches soil that ravels between shores. The load passes to the uprights or rails; the plywood is not the primary structural member. [5] [4]

OSHA's April 15, 1992 interpretation letter states the same point in dated language. It explains that note (g)(7) applies only to Tables D-1.1 through D-1.4 where an employer designs under §1926.652(c)(1), Option (1), and that the plywood in that note is not a substitute for primary load-carrying structural members such as timber uprights or aluminum rails. Its stated function is to contain raveled soil and transfer those loads to the load-carrying members. [4] [5]

A different route: for the six Tren-Shore models on its November 2025 cover, Kundel directs the competent person to its tabulated data (p. 25, §2.3). Those data depend on shores in good structural condition (p. 26, §4.3). The sheeting and soil provisions, including the reference to Finn Form, appear together on p. 27, §§6.6–6.8. They are not a specification for an unidentified shore. [7] [3]

What the Fin Form name identifies

If you are holding a panel that someone called Fin Form and need to know whether it can go behind a vertical shore in trench shoring, the answer starts with documents rather than with the panel's surface. In US federal excavation rules the term appears only as a parenthetical inside a footnote; in product literature it appears as a brand name used by a company. Those are not the same claim, and neither one tells you what your unit is. A construction team should treat the name as a lead, not a finding. [5] [6]

Appendix D footnote (g)(7) names arctic white birch plywood for raveling control between shores. OCM sells a birch-faced panel as Finn Form. Kundel lists that brand among sheeting examples for the Tren-Shore models identified in its manual. [5] [6] [7]

OCM’s undated product sheet describes the faces and phenolic bond of its panel. It does not identify a shore system or establish that another panel is an acceptable substitute. [6]

Appendix D is not a general plywood specification

§1926.650 defines sheeting as the members of a shoring assembly that retain earth in position and are supported by other members, and shoring as a structure such as a metal hydraulic, mechanical or timber arrangement that supports the sides of an excavation and is designed to prevent cave-ins. Uprights are vertical members placed in contact with the earth; closely spaced, interconnected uprights are often called sheeting. Wales are horizontal members parallel to the excavation face that bear against the vertical members or the earth, and cross braces bear against uprights or wales; in aluminum hydraulic shoring the cylinders act as those cross braces. [1]

Appendix D is narrower than the phrase “trench shoring” suggests. It covers aluminum hydraulic shoring — one metal system among several — in trenches no deeper than 20 feet, and it must be used when the design cannot follow §1926.652(c)(2), for example when a manufacturer's tabulated data is not available. Tables D-1.1 and D-1.2 cover vertical shores; D-1.3 and D-1.4 cover wale systems, where the vertical timber sheeting comes from the same tables. Paragraph (d) lists cases — vertical loads on the cylinder, surcharges from heavy equipment, some partly shored trenches — where the tabulated members are not considered adequate and another design is required. [5] [3]

In its 1992 letter, OSHA accepts another plywood type or thickness under Option (1) only if it provides equal or better strength and stiffness than the plywood in the footnote. Matching the nominal thickness alone does not meet that test. [4]

Plywood sheeting can appear behind a shore under other routes, but the requirements differ. The 1992 letter notes that a design under §1926.652(c)(3), Option (3), must meet that subsection's requirements and is not bound by the appendix; paragraph (c)(3) requires written tabulated data identifying the parameters that affect selection, the limits of use, explanatory information, and a copy at the jobsite identifying the engineer who approved it. That separate path carries its own paperwork; it is not a general permission. [4] [3]

A panel data sheet and a shore system manual answer different questions

Use the OCM sheet to identify the panel and the Kundel manual to check the covered shore models and arrangements. Neither a similar face material nor the date on a manual establishes that it covers the unit at hand. [7] [3] [6]

Record the panel marking and product sheet separately from the shore manufacturer, model, configuration, manual revision and governing design route. A match on the face material does not establish a match on the rest of the assembly. [6] [7] [3]

The route entry deserves its own line because the four options impose different records. Option (1) works from appendices A, C and D. Option (2) works from the manufacturer's tabulated data, with deviations allowed only on the manufacturer's specific written approval and that data kept at the jobsite during construction. Option (3) works from other tabulated data satisfying paragraph (c)(3). Option (4) is a design approved by a registered professional engineer in written form, with a plan indicating sizes, types and configurations and identifying that engineer. [3]

Damage and changes in site conditions

§1926.652(d) sets the material conditions. Paragraph (d)(1) requires anything used for a protective system to be free from damage or defects that might impair proper function. Paragraph (d)(2) requires manufactured materials and equipment to be used and maintained consistently with the manufacturer's recommendations, and in a manner that prevents employee exposure to hazards. Both are continuing conditions, not one-time items, and questions about condition, moisture and earlier use stay open. [3] [7]

Paragraph (d)(3) is the conditional part, and it applies when material or equipment is damaged. A competent person must examine it and evaluate suitability for continued service. Only where that person cannot assure the material or equipment is able to support the intended loads, or is otherwise suitable for safe use, does it come out of service and require evaluation and approval by a registered professional engineer before it is returned to service. That step follows a failed assurance rather than a routine inspection; it is not a signoff on every record entry. [3]

Under §1926.651(k)(1), when employee exposure can reasonably be anticipated, the competent person inspects the excavation, adjacent areas and protective systems before work starts, as needed throughout the shift, and after every rainstorm or other hazard-increasing occurrence. If an inspection identifies a possible cave-in, protective-system failure or other hazardous condition, exposed employees must be removed until necessary precautions are taken. [2]

Sources

  1. 29 CFR 1926.650: Scope, application, and definitions applicable to this subpartOccupational Safety and Health Administration
  2. 29 CFR 1926.651: Specific excavation requirementsOccupational Safety and Health Administration
  3. 29 CFR 1926.652: Requirements for protective systemsOccupational Safety and Health Administration
  4. Use of plywood for shoring and support systems in trenches and excavations (interpretation, April 15, 1992)Occupational Safety and Health Administration
  5. 29 CFR 1926 Subpart P, Appendix D: Aluminum Hydraulic Shoring for TrenchesOccupational Safety and Health Administration
  6. OCM Finn Form Product Data SheetOCM Inc.